Question 66
A storage administrator receives reports of network delays when database software attempts to access the storage array. The virtual machines that host the database software are installed on different rack servers connected to the Cisco UCS Fabric Interconnect domain. The existing SAN switches are connected to the Fabric Interconnects using two 8 Gb port-channel interfaces to connect the storage array. The storage administrator has decided to deploy iSCSI storage with four 10 Gbps interfaces connected to the Cisco UCS Fabric Interconnects.
Which deployment type resolves the problems with storage contention?
Which deployment type resolves the problems with storage contention?
Question 67
Which two types of service profile templates does Cisco UCS support? (Choose two.)
Question 68
A company's data center is currently running on a traditional SAN architecture with Cisco UCS C200 M5 Blade Servers, producing 1000 IOPS The SAN is becoming a performance bottleneck, so management decided to implement a new solution to provide better performance and scalability. The preferred solution must meet these requirements:
* Provide at least 10x the performance of the current SAN
* Provide up to 100 Gbps of throughput per node
* Be easily scalable to meet the future needs of the enterprise
Which solution must the company deploy to meet the requirements9
* Provide at least 10x the performance of the current SAN
* Provide up to 100 Gbps of throughput per node
* Be easily scalable to meet the future needs of the enterprise
Which solution must the company deploy to meet the requirements9
Question 69
Refer to the exhibit.

A high-availability setup for iSCSI is designed with the host running iSCSI multipath software. Each IP storage port on the MDS switch exports the same two Fibre Channel target ports with different iSCSI target names.
In this design, how many iSCSI sessions are created from the host so that recovery occurs if any component fails?

A high-availability setup for iSCSI is designed with the host running iSCSI multipath software. Each IP storage port on the MDS switch exports the same two Fibre Channel target ports with different iSCSI target names.
In this design, how many iSCSI sessions are created from the host so that recovery occurs if any component fails?
Question 70
A network consultant reviews the requirements for the Storage Area Network (SAN) design. The proposed solution must offer a very efficient port usage and eliminate the need for a separate physical layer of switches and their associated ISLs. The design is not expected to require future expansion.
Which SAN topology must be used to meet these requirements?
Which SAN topology must be used to meet these requirements?