- Home
- EDGE Certification
- EDGE-Expert Exam
- EDGE.EDGE-Expert.v2026-03-28.q27 Practice Test
Question 1
Water consumption savings, resulting from greywater recovery, are based on which of the following?
Correct Answer: A
Greywater recovery in EDGE is a water efficiency measure, and the software calculates savings by comparing water consumption before and after implementing the measure. The EDGE Methodology Report explains the calculation method: "Water consumption savings from greywater recovery are calculated as the difference between the Base Case water consumption and the Improved Case water consumption after applying the measure. The Base Case represents the typical water use without any efficiency measures, serving as the benchmark for all savings calculations" (EDGE Methodology Report Version 2.0, Section 4.2: Water Savings Calculations). Option A, Base Case water consumption, is the correct reference point for determining savings, as it establishes the baseline against which the greywater recovery measure is evaluated. Option B (Improved Case water consumption) is the result after applying the measure, not the basis for savings. Option C (cost of water consumption at local tariff) and Option D (incremental cost of installation and cost of water consumption at local tariff) relate to financial outputs, not the direct calculation of water savings, as clarified:
"Water savings in EDGE are quantified in volume (liters or cubic meters), not cost, though cost savings are derived later using local tariffs" (EDGE User Guide, Section 5.2: Water Efficiency Measures). Thus, greywater recovery savings are based on Base Case water consumption (Option A).
Reference:EDGE Methodology Report Version 2.0, Section 4.2: Water Savings Calculations; EDGE User Guide Version 2.1, Section 5.2: Water Efficiency Measures.
"Water savings in EDGE are quantified in volume (liters or cubic meters), not cost, though cost savings are derived later using local tariffs" (EDGE User Guide, Section 5.2: Water Efficiency Measures). Thus, greywater recovery savings are based on Base Case water consumption (Option A).
Reference:EDGE Methodology Report Version 2.0, Section 4.2: Water Savings Calculations; EDGE User Guide Version 2.1, Section 5.2: Water Efficiency Measures.
Question 2
Utility cost savings are calculated based on reduction in total:
Correct Answer: D
Utility cost savings in EDGE are calculated based on reductions in resource consumption sourced from the supply grid, as these are the costs directly borne by the building owner. The EDGE User Guide explains:
"Utility cost savings in EDGE are calculated based on the reduction in energy and water consumption from the supply grid, using local tariffs for electricity and water to convert resource savings into financial savings" (EDGE User Guide, Section 2.4: Interpreting EDGE Results). Option D, energy and water consumption from the supply grid, aligns with this definition, focusing on grid-supplied resources. Option A (electricity and water consumption) is partially correct but lacks specificity about the source: "Electricity and water must be grid-supplied to be included in utility cost savings; onsite generation is excluded" (EDGE Methodology Report Version2.0, Section 4.4: Cost Savings Calculations). Option B (generator fuel and water consumption) is incorrect, as generator fuel is not part of utility cost savings: "Generator fuel costs are not included in utility savings, as EDGE focuses on grid-supplied utilities" (EDGE User Guide, Section 2.4: Interpreting EDGE Results). Option C (building energy and water consumption) is too broad, including onsite sources: "Building consumption includes all sources, but utility savings are grid-specific" (EDGE Methodology Report Version
2.0, Section 4.4: Cost Savings Calculations). Thus, energy and water from the supply grid (Option D) is the correct basis for utility cost savings.
Reference:EDGE User Guide Version 2.1, Section 2.4: Interpreting EDGE Results; EDGE Methodology Report Version 2.0, Section 4.4: Cost Savings Calculations.
"Utility cost savings in EDGE are calculated based on the reduction in energy and water consumption from the supply grid, using local tariffs for electricity and water to convert resource savings into financial savings" (EDGE User Guide, Section 2.4: Interpreting EDGE Results). Option D, energy and water consumption from the supply grid, aligns with this definition, focusing on grid-supplied resources. Option A (electricity and water consumption) is partially correct but lacks specificity about the source: "Electricity and water must be grid-supplied to be included in utility cost savings; onsite generation is excluded" (EDGE Methodology Report Version2.0, Section 4.4: Cost Savings Calculations). Option B (generator fuel and water consumption) is incorrect, as generator fuel is not part of utility cost savings: "Generator fuel costs are not included in utility savings, as EDGE focuses on grid-supplied utilities" (EDGE User Guide, Section 2.4: Interpreting EDGE Results). Option C (building energy and water consumption) is too broad, including onsite sources: "Building consumption includes all sources, but utility savings are grid-specific" (EDGE Methodology Report Version
2.0, Section 4.4: Cost Savings Calculations). Thus, energy and water from the supply grid (Option D) is the correct basis for utility cost savings.
Reference:EDGE User Guide Version 2.1, Section 2.4: Interpreting EDGE Results; EDGE Methodology Report Version 2.0, Section 4.4: Cost Savings Calculations.
Question 3
Which type of evidence is required at the post-construction stage for the efficiency measure window glazing?
Correct Answer: B
The post-construction stage in EDGE certification requires evidence to confirm that the efficiency measures claimed in the design stage have been implemented as specified. For window glazing, which affects energy efficiency through its U-value (thermal transmittance) and SHGC (Solar Heat Gain Coefficient), the EDGE Certification Protocol provides clear requirements: "At the post-construction stage, the Client must provide manufacturer's data sheets for the window glazing measure, showing the make and model, U-value, and SHGC of the installed glass, to confirm that the glazing matches the specifications claimed in the self- assessment and meets the energy efficiency requirements" (EDGE Certification Protocol, Section 3.4: Post- Construction Requirements). Option C, manufacturer's data sheets showing the make and model, U-value, and SHGC of the installed glass, directly matches this requirement, as it provides the specific technical data needed to verify compliance. Option A (design building elevations marking the window glass specifications) is relevant at the design stage, not post-construction: "Design elevations are required at the preliminary stage to show intended glazing specifications, not after construction" (EDGE Certification Protocol, Section 3.2:
Audit Requirements). Option B (bill of quantities with specifications highlighted) is insufficient on its own, as it may not provide detailed technical data: "Bills of quantities may support purchase verification, but manufacturer's data sheets are required for technical specifications like U-value and SHGC" (EDGE Certification Protocol, Section 3.4: Post-Construction Requirements). Option D (window schedule showing major glass types) is helpful but not sufficient, as it lacks the detailed technical data: "Window schedules may indicate glass types, but they do not replace the need for manufacturer's data sheets with U-value and SHGC at post-construction" (EDGE User Guide, Section 6.2: Documentation Requirements). The EDGE User Guide further clarifies: "For glazing measures, post-construction evidence must confirm the installed product's performance through manufacturer's data sheets, ensuring alignment with the design-stage claims" (EDGE User Guide, Section 4.1: Insulation Measures). Thus, manufacturer's data sheets (Option C) are required at the post-construction stage.
Reference:EDGE Certification Protocol, Section 3.4: Post-Construction Requirements, Section 3.2: Audit Requirements; EDGE User Guide Version 2.1, Section 6.2: Documentation Requirements, Section 4.1:
Insulation Measures.
Audit Requirements). Option B (bill of quantities with specifications highlighted) is insufficient on its own, as it may not provide detailed technical data: "Bills of quantities may support purchase verification, but manufacturer's data sheets are required for technical specifications like U-value and SHGC" (EDGE Certification Protocol, Section 3.4: Post-Construction Requirements). Option D (window schedule showing major glass types) is helpful but not sufficient, as it lacks the detailed technical data: "Window schedules may indicate glass types, but they do not replace the need for manufacturer's data sheets with U-value and SHGC at post-construction" (EDGE User Guide, Section 6.2: Documentation Requirements). The EDGE User Guide further clarifies: "For glazing measures, post-construction evidence must confirm the installed product's performance through manufacturer's data sheets, ensuring alignment with the design-stage claims" (EDGE User Guide, Section 4.1: Insulation Measures). Thus, manufacturer's data sheets (Option C) are required at the post-construction stage.
Reference:EDGE Certification Protocol, Section 3.4: Post-Construction Requirements, Section 3.2: Audit Requirements; EDGE User Guide Version 2.1, Section 6.2: Documentation Requirements, Section 4.1:
Insulation Measures.
Question 4
Which of the following is NOT a characteristic of the EDGE standard?
Correct Answer: B
The EDGE standard is designed to be a practical, focused tool for green building certification, emphasizing specific resource efficiency metrics. The EDGE User Guide describes its characteristics: "EDGE is a simple, fast, and smart tool for green building certification. It provides an intuitive interface with a powerful engine that accounts for local climate and building use (simple), identifies measures with the best return on investment (fast), and displays capital costs and payback periods (smart)" (EDGE User Guide, Section 1.1:
Introduction to EDGE). Options A, C, and D align with these descriptions. However, Option B (holistic approach that takes into account wider sustainability issues) is not a characteristic of EDGE, as the standard focuses narrowly on energy, water, and embodied energy in materials, not broader sustainability issues like biodiversity or social equity. This is clarified in the EDGE Certification Protocol: "EDGE is not a holistic sustainability standard; it specifically targets resource efficiency in energy, water, and materials, excluding wider sustainability metrics such as indoor air quality or ecological impact" (EDGE Certification Protocol, Section 1.2: Scope of EDGE Standard). Thus, Option B is not a characteristic of the EDGE standard.
Reference: EDGE User Guide Version 2.1, Section 1.1: Introduction to EDGE; EDGE Certification Protocol, Section 1.2: Scope of EDGE Standard.
Introduction to EDGE). Options A, C, and D align with these descriptions. However, Option B (holistic approach that takes into account wider sustainability issues) is not a characteristic of EDGE, as the standard focuses narrowly on energy, water, and embodied energy in materials, not broader sustainability issues like biodiversity or social equity. This is clarified in the EDGE Certification Protocol: "EDGE is not a holistic sustainability standard; it specifically targets resource efficiency in energy, water, and materials, excluding wider sustainability metrics such as indoor air quality or ecological impact" (EDGE Certification Protocol, Section 1.2: Scope of EDGE Standard). Thus, Option B is not a characteristic of the EDGE standard.
Reference: EDGE User Guide Version 2.1, Section 1.1: Introduction to EDGE; EDGE Certification Protocol, Section 1.2: Scope of EDGE Standard.
Question 5
Which of the following parameters can be found in the EDGE App Results Bar?
Correct Answer: C
The EDGE App Results Bar displays key outputs of the software analysis after a project is modeled. The EDGE User Guide details the contents of the Results Bar: "The EDGE App Results Bar provides a summary of the project's performance, including percentage savings in energy, water, and embodied energy in materials, as well as the incremental cost, payback period, and carbon emissions reduction" (EDGE User Guide, Section 2.4: Interpreting EDGE Results). Option C, incremental cost, is explicitly mentioned as part of the Results Bar, representing the additional cost of implementing green measures. Option A (building type) and Option B (occupant use) are inputs specified by the user during project setup, not outputs in the Results Bar, as noted: "Building type and occupant use are input parameters, not displayed in the Results Bar" (EDGE User Guide, Section 2.2: Project Setup). Option D (climate conditions) is also an input parameter (selected via location), not an output: "Climate conditions are derived from the selected location and are not shown in the Results Bar" (EDGE Methodology Report Version 2.0, Section 3.2: Climate Data Inputs). Thus, incremental cost (Option C) is the correct parameter found in the Results Bar.
Reference: EDGE User Guide Version 2.1, Section 2.4: Interpreting EDGE Results, Section 2.2: Project Setup; EDGE Methodology Report Version 2.0, Section 3.2: Climate Data Inputs.
Reference: EDGE User Guide Version 2.1, Section 2.4: Interpreting EDGE Results, Section 2.2: Project Setup; EDGE Methodology Report Version 2.0, Section 3.2: Climate Data Inputs.
- Other Version
- 300EDGE.EDGE-Expert.v2026-07-22.q39
- Latest Upload
- 174NAHQ.CPHQ.v2026-09-03.q481
- 113SAP.C-S4CPB-2602.v2026-09-02.q7
- 109Cisco.700-805.v2026-09-02.q86
- 161MSSC.CLT-4.0.v2026-09-02.q43
- 126Fitness.NCSF-CPT.v2026-09-02.q18
- 174Google.Generative-AI-Leader.v2026-09-02.q77
- 139PECB.ISO-14001-Lead-Auditor.v2026-09-01.q39
- 126Google.GCP-DE.v2026-09-01.q27
- 160Cisco.300-820.v2026-09-01.q105
- 154Cisco.500-220.v2026-09-01.q72
[×]
Download PDF File
Enter your email address to download EDGE.EDGE-Expert.v2026-03-28.q27 Practice Test
