Question 21
A consultant needs to review a customer's switch port configuration to identify any issues. Other customer requirements are as follows:
* Leverage LACP
* Native VLAN will not be used
* Use Multiple Upstream switches
* Use VLANs 20-25 and 30
* LACP Fallback has been Enabled
* vPC or MLAG has been configured
What must be included in a configuration in order to meet these requirements?
* Leverage LACP
* Native VLAN will not be used
* Use Multiple Upstream switches
* Use VLANs 20-25 and 30
* LACP Fallback has been Enabled
* vPC or MLAG has been configured
What must be included in a configuration in order to meet these requirements?
Question 22
A customer has an ESXi Cluster with two 10GbE NICs on each node with the following requirements:
* Solution must follow Nutanix Best Practices
* Network configuration should be redundant
* A vSphere Standard Switch must be utilized
Which load balancing method should be used?
* Solution must follow Nutanix Best Practices
* Network configuration should be redundant
* A vSphere Standard Switch must be utilized
Which load balancing method should be used?
Question 23
A customer has Metro Availability configured in Automatic Resume Mode between Site A and Site B What happens to VMs if Primary Site A has full network failure?
Question 24
A consultant is imaging a Nutanix cluster with VMware ESXi. Foundation returns an error that the media is not a supported ISO. The consultant checks the whitelist file in Foundation and confirms that the version of the ISO is not listed.
Which three actions should the consultant take to resolve this issue? (Choose three.)
Which three actions should the consultant take to resolve this issue? (Choose three.)
Question 25
An administrator receives a notification that storage in a Nutanix cluster is unavailable. The cluster consists of five nodes and is configured with a Fault-Tolerance level of 1 (FT-1).
Upon investigation, the administrator finds the following:
* All AHV hosts are powered on and the CVMs are running
* Nodes A, B, and C are connected to one top of rack switch
* Nodes D and E are connected to a second top of rack switch
* The cluster status command run on Node A shows that CVM services on nodes D and E are down Which issue is causing the storage outage?
Upon investigation, the administrator finds the following:
* All AHV hosts are powered on and the CVMs are running
* Nodes A, B, and C are connected to one top of rack switch
* Nodes D and E are connected to a second top of rack switch
* The cluster status command run on Node A shows that CVM services on nodes D and E are down Which issue is causing the storage outage?